Vibro-meter 200-560-000-113 IOC4T

Vibro-meter 200-560-000-113 IOC4T

Manufacturer: Vibro-meter

Model: 200-560-000-13 IOC4T

Shipping weight: 5Kg

Quantity: 1

Warranty period: from 1 year

Imported: Yes

Available for sale: worldwide

Category:
Email: Jiedong@sxrszdh.com
Phone: +86 15340683922
Sales:Wu Jiedong
Our products are guaranteed for 1 year, with new and original production stopped and imported spare parts.
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our warranty: All new or repaired parts have a 12 month warranty period beginning
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!

Description

Vibro-meter 200-560-000-113 IOC4T
Dynamic signal inputs
Filtering : Filtered for protection against electromagnetic interference
(conforms to EC standards).
Refer to the VM600 MPC4 machinery protection card data sheet
for further information.
Buffered dynamic signal outputs
Filtering : Filtered for protection against electromagnetic interference
(conforms to EC standards).
Refer to the VM600 MPC4 machinery protection card data sheet
for further information.
Speed/phase reference inputs
Filtering : Filtered for protection against electromagnetic interference
(conforms to EC standards).
Refer to the VM600 MPC4 machinery protection card data sheet
for further information.
Discrete signal interface (DSI) inputs
Control signal
a1d3991a52d5f6543237 1 Vibro-meter 200-560-000-113 IOC4T

c95c1f4269b1db990a36 1 Vibro-meter 200-560-000-113 IOC4T
• Alarm reset (AR) : A closed contact between the DSI AR and DSI RET inputs resets
(clears) the alarms latched by the MPC4/IOC4T card pair.
Note: The alarm reset input (DSI AR) is edge-sensitive and a high-tolow transition is required to activate the reset.
• Danger bypass (DB) : A closed contact between the DSI DB and DSI RET inputs inhibits
(bypasses) the danger relay outputs
• Trip multiply (TM) : A closed contact between the DSI TM and DSI RET inputs multiplies
the alarm levels by a scale factor (software configurable), to
enable adaptive monitoring.
Operating principle : Detection of an open circuit or a closed circuit on the input
Alarm outputs
Alarm relays : 4 per IOC4T card.
The MPC4 card can drive the four local relays on the IOC4T card,
as well the relays on RLC16 relay cards and/or IRC4 intelligent relay
cards using the VM600 rack’s Raw bus or Open Collector (OC) bus.
For IOC4T card relay features, see Relay characteristics on page 4.
For further information on RLC16 or IRC4 relay cards, refer to the
corresponding data sheet.
Note: In a VM600 rack (ABE4x), the Open Collector (OC) bus and/or Raw bus can be used to connect up to
32 outputs from an MPC4/IOC4T card pair to RLC16 relay cards or IRC4 intelligent relay cards in the same rack,
if additional relays are required.

Email: Jiedong@sxrszdh.com
Phone: +86 15340683922
Sales:Wu Jiedong
Our products are guaranteed for 1 year, with new and original production stopped and imported spare parts.
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our warranty: All new or repaired parts have a 12 month warranty period beginning
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!