Port B is routed (via the module at J10) to the 25-pin DB25 connector marked

SERIAL PORT 2 on the MVME162 front panel. Port B is also routed to a DB9 (on

the MVME712x) or DB25 (on the MVME712M) connector on the MVME712

series transition module. It is identified there as Port 4.

Although both ports are connected to the same Z85230 Port B, there are several

considerations to keep in mind:

❏ On the MVME162 front panel, Port 2 can be connected to the TxC and RxC

clock signals which may be present on the DB25 connector. These

connections are made via header J12 on the MVME162 board (see Figures

2-3, 2-4, and 2-5 in Chapter 2). The TxC and RxC clock lines are also

available at Port 4 on MVME712M transition modules.

❏ On MVME712x transition modules, Port 4 is hard-wired as an EIA-232-D

DB9 DTE serial port. A ‘‘null modem’’ cable is necessary to use it as a DCE

port.

❏ On MVME712M transition modules, Port 4 can be configured as either a

DTE or DCE EIA-232-D serial port via jumper headers J19 and J18 on the

MVME712M. Port 4 can also be connected to the TxC and RxC clock

signals which may be present on the DB25 connector. These connections

are made via header J15 on the MVME712M (see Figure 2-3, sheets 3-6 in

Chapter 2).

❏ When Port B is configured as an EIA-530 interface, EIA-530 data transfers

normally occur through serial port 2 on the MVME162 front panel. The

MVME712 series transition module should be disconnected from the

MVME162.

Category:
Email: Jiedong@sxrszdh.com
Phone: +86 15340683922
Sales:Wu Jiedong
Our products are guaranteed for 1 year, with new and original production stopped and imported spare parts.
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our warranty: All new or repaired parts have a 12 month warranty period beginning
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!

Description

MVME162-211

Port A of the Z85230 is interfaced as EIA-232-D DCE (data circuit-terminating

equipment) and is routed to the 25-pin DB25 connector marked SERIAL PORT

1/CONSOLE on the MVME162 front panel. Port A is also routed to a DB9/RJ11

(on the MVME712x) or DB25 (on the MVME712M) connector on the

MVME712 series transition module. It is identified there as Port 2.

Although both ports are connected to the same Z85230 Port A, there are

several differences between them:

❏ On the MVME162 front panel, Port 1 can be connected to the TxC and RxC

clock signals which may be present on the DB25 connector. These

connections are made via header J11 on the MVME162 board (see Figures

2-3 and 2-4 in Chapter 2). The TxC and RxC clocks are not available at Port

2 on the MVME712 series transition modules.

❏ On MVME712x transition modules, Port 2 can be routed either through a

DB9 DTE serial interface or (if the module is so equipped1) through the

onboard modem and its standard RJ11 (Telco) jack. These connections are

made via jumper headers J16 and J17 on the MVME712x.

❏ On MVME712M transition modules, Port 2 can be configured as either a

DCE or a DTE serial port via jumper headers J16 and J17 on the

MVME712M.

Figures 2-3 (sheets 1 and 2) and 2-4 (sheets 1 and 2) in Chapter 2 illustrate the

configurations available for Port A.

MVME162-200

MVME162-200

MVME162-200

MVME162-200

MVME162-211

MVME162-211

Email: Jiedong@sxrszdh.com
Phone: +86 15340683922
Sales:Wu Jiedong
Our products are guaranteed for 1 year, with new and original production stopped and imported spare parts.
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our warranty: All new or repaired parts have a 12 month warranty period beginning
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!