DS200FGPAG1AHD Gate pulse amplifier board

DS200FGPAG1A Technical Specifications

Compatibility Not Backwards Compatible

Number of Gate Driver Circuits Two

Number of Test Points 30, Nine for Gate A, Nine for Gate B, and 12 for Cell Status Monitors

Part Specific Manual GEI-100223

Quantity of Fiber-Optic Connectors 15, One Fiber-Optic Transmitter, and Fourteen Fiber-Optic Receivers

Series LS2100

Twelve-Pulse Convertor Supply Voltage 2080 or 3300 VAC

In order to complete the control strategy, replace the relay, and enable the user to complete the ladder diagram of the control system similar to the relay circuit, a set of control algorithm function blocks (or subprograms), called the instruction system, is compiled and solidified in the memory ROM, which can be called by the user when compiling the application program. The instruction system can be roughly divided into two categories: basic instructions and extended instructions. The instruction system of general PLC includes: basic instruction, timer/counter instruction, shift instruction, transfer instruction, comparison instruction, conversion instruction, BCD operation instruction, binary operation instruction, increment/decrement instruction, logic operation instruction, special operation instruction, etc. These instructions are similar to assembly language. In addition, PLC also improves sufficient internal resources such as timer, counter, internal relay, register and storage area, which brings great convenience for programming.

Category:
Email: Jiedong@sxrszdh.com
Phone: +86 15340683922
Sales:Wu Jiedong
Our products are guaranteed for 1 year, with new and original production stopped and imported spare parts.
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our warranty: All new or repaired parts have a 12 month warranty period beginning
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!

Description

Frequently Asked Questions about DS200FGPAG1A
There are three main functions on the DS200FGPAG1A board. What are they and what do they do?

The three main functions are switching the power supply, gate driver, and SCR status monitoring. The purpose of the power supply switching function is to convert the received AC voltages into the required DC voltages needed for gating and status functions. The purpose of the SCR status monitoring is to accumulate cell voltage information from the attached FHVAs and relay the information via an optical serial data link to the LCI controller. The gate driver is used to supply any gate power for one phase of an SCR bridge. More information regarding these functions can be found on the front page of the GEI-100223 Gate Pulse Amplifier User’s Guide.

There are thirty test points on the DS200FGPAG1A board between Gate A, Gate B, and the test points for Cell Status Monitoring. What are the descriptions for the test points in Gate A?

There are nine test points in Gate A, and many of them have individual descriptions with different nomenclatures, some are as follows: TP101, nomenclature 1PUSH1, description Logic 1= command to start to push cycle; TP105, nomenclature VLINKA, description primary voltage; and TP110, nomenclature 0RELA, description Logic 0 = release gate inhabits.

What is the acceptable power input for the Gate Pulse Amplifier Board?

The FGPA will accept a power input of 120 Vrms Ù 20%, 50/60 Hz, approximately 350 VA maximum. There are four different points on the FGPA model than can accept voltages which are as follows, P15 while not monitored will typically accept a power supply of 13.5-14.5 VDC, P5 accepts voltages between 4.7-5.1 VDC, P90 accepts greater than or equal to 81 VDC, and P40 will accept greater than or equal to 25 VDC.

DS200FGPAG1AHD

DS200FGPAG1AHD

d1ce880cf50b643d9aba 3 DS200FGPAG1AHD Gate pulse amplifier board

4f3114a3c2c1b64fbef6 3 DS200FGPAG1AHD Gate pulse amplifier board

Email: Jiedong@sxrszdh.com
Phone: +86 15340683922
Sales:Wu Jiedong
Our products are guaranteed for 1 year, with new and original production stopped and imported spare parts.
All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager).
Our product: brand new original packaging
Our warranty: All new or repaired parts have a 12 month warranty period beginning
Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed!
If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!